Creating Screens
This topic is subject to expert review. Please provide any feedback to Alemba Support.
You can create details windows and portal review screens using the Designer.
Details windows are used to create entities in vFire Core, such as Calls, Knowledge articles, Bulletin Board entries, Tasks, Requests and so on. Portal review screens are used to display the details of entities created in the main application on the vFire Self Service portal.
Before you start
You must have Designer selected in your General Access Security Role.
You should understand the concepts of screen sets.
Multiple screen sets must be enabled in the IPK or Workflow Management settings if you are using custom screen sets.
If you wish to use custom screens, custom screen sets must have been defined in IPK and Workflow administration.
To maintain an audit trail of changes made to screens, forms and message templates, Designer must be selected in the Auditing window.
-
Display the Designer window if it is not already visible on screen.
Select
and then Admin.
From the submenu, select Designer.
This window consists of three tabs. They display different views:
Find a Screen Can be used to search for and work with specific screens, forms or message templates, as well as create new in-house screens View screens Displays details of currently selected screens and is used to modify screens Skins Enables you to create and modify skins for your vFire Self Service Portal(s) - Select a screen type from the Screens list in the left pane to populate the browse table and activate the buttons at the bottom of the window.
- Select
at the bottom of the window. The Screen Details window is displayed, with some of the details completed based on your Screen selection.
- Complete the details:
- Select OK to create the new screen. You are returned to the main Find a Screen view of the Designer window. An entry for the new screen appears in the browse table.
- You should test the new screen before live release to ensure there are no unexpected results.
- Give Analysts access to the new screen through their IPK or Workflow security role if necessary.
Create | A drop-down list of different entities you can create. Select Screen if necessary. | ||||||
Name | A drop-down list of system defined names. Screen names for details windows follow the naming convention “[Entity] Details”, for example “Call Details”. The name you selected should be displayed. Select from the drop-down list if necessary.
|
||||||
Screen Set |
The screen set to which the new screen must be associated. You cannot select a screen set which already has an active screen for the name you chose. If you choose Call Details, no screen sets are available if no custom call screen sets have been defined. However, if you choose Call Submission, the Incident, Known Error, Major Incident, Problem, and Service Desk screen sets will all be available, as these do not have a default submission form associated with them; in this case you cannot select the default screen set, Call, as it already contains a default submission form.
If you selected Knowledge as the entity, this list displays the visible Knowledge Base types. If you selected CMDB Item, it displays the CMDB Item sub-types. |
||||||
Copy From | Select an existing screen on which to base your new one. The list displays the names of all existing active screens with the name you selected at Name. The naming convention for the screens in this list is “[screen set name] [screen name]" |
If you try to create a screen and an inactive (deleted) screen already exists with the same name, you will receive a warning message asking you if you want to permanently remove the deleted screen from the database and create the new screen. Select Yes to continue, or No to cancel the screen creation. You can restore deleted screens if you wish.
Creating a Portal Submission Screen
Portal submission screens can be used for logging requests and calls through the vFire Self Service portal. Users only need to be able to complete information which is relevant to them as an end-user.
Analysts with the required permissions can create and link a portal submission screen to a call template or workflow template. Access to call templates and workflow templates is given via the relevant tabs on the Self Service Portal role. Users and other Analysts can then use the template, complete the fields, and submit the call or request. This will generate a call or request in the main application.
The Designer enables organizations to add additional configured fields to a call template or workflow template.
Before you start
You must have Designer selected in your General Access Security Role.
You should understand the concepts of screen sets.
Remember to enable multiple screen sets in the IPK or Workflow Management settings.
If you wish to use custom screens, define custom screen sets in IPK and Workflow administration.
To maintain an audit trail of changes made to screens, forms and message templates, Designer must be selected in the Auditing window.
-
Display the Designer window if it is not already visible on screen.
Select
and then Admin.
From the submenu, select Designer.
This window consists of three tabs. They display different views:
Find a Screen Can be used to search for and work with specific screens, forms or message templates, as well as create new in-house screens View screens Displays details of currently selected screens and is used to modify screens Skins Enables you to create and modify skins for your vFire Self Service Portal(s) - Select a screen type from the Screens list in the left pane to populate the browse table and activate the buttons at the bottom of the window.
- Select
at the bottom of the window. The Screen Details window is displayed, with some of the details completed based on your Screen selection.
- Complete the details:
- To view the screen details, select
from the bottom of the window.
- To make the screen available, you must associate it with the relevant template.
Create | A drop-down list of different entities you can create. Select Screen if necessary. | ||||||
Name |
A drop-down list of system defined names. Screen names for details windows follow the naming convention “[Entity] Details”, for example “Call Details”. The name you selected should be displayed. Select from the drop-down list if necessary.
|
||||||
Screen Set |
The screen set to which the new screen must be associated. You cannot select a screen set which already has an active screen for the name you chose. If you selected Knowledge as the entity, this list displays the visible Knowledge Base types, that is, the Knowledge entry types defined by the system administrator. If you selected CMDB Item as the entity, this list displays the CMDB Item sub-types defined by the system administrator. |
||||||
Copy From | Select an existing screen on which to base your new one. The list displays the names of all existing active screens with the name you selected at Name. The naming convention for the screens in this list is “[screen set name] [screen name]" |